Inderm PSI: Instructions

 
Installing the Syringe

Standard B-D Luer-Lock ® syringes (1, 3, 5, or 10 ml/cc) are recommended for use with the Inderm-PSI device. To install the syringe, lift open the door of the syringe driver and slide it as far back as is needed to clear the syringe. Next, point the tip of the needle into the guard carefully and then drop the syringe plunger into the appropriate slot of the driver. Slide the syringe forward until it is fully seated against the cradle and tighten the syringe cradle knob. DO NOT OVER TIGHTEN THE SYRINGE CRADLE KNOB. The needle should not protrude beyond the needle guard. There is a syringe stop located in the cradle to prevent the syringe from sliding forward even if the knob is loose. Close the door of the driver to secure the syringe. The device will not operate unless the door of the syringe driver is closed. Verify that the syringe and needle are purged of air before starting injections.
  Selecting the Function
To turn the Inderm PSI ™ on, press and hold the power button for 3 seconds and the power light will glow indicating that the device is on. Once the power is on, there is no default function on the device. When the activation button is pressed, nothing will happen until operating parameters are selected.
 
Deactivating the Needle Guard

** The device can be activated by either pressing the activation button or pressing the needle guard into the device. If you wish, you may deactivate the needle guard by turning the device on and before selecting any parameters, press and hold the activation button for 10 seconds. The device will beep when you initially press the activation button, continue to press the activation button for 10 seconds until the device beeps a second time. The device will now only be activated by pressing the activation button. To reset the system, to allow for the activation of the device using the needle guard, you must turn the device off, turn it back on, and press and hold the activation button for 10 seconds. Again, the device will beep when you initially press the activation button, continue to press the activation button for 10 seconds until the device beeps a second time.
 
Continuous Mode, Drop A/B Mode, Micro Shots

 
 
Volume per Injection
Syringe Size Drop A Drop B Micro shots

1 ml

0.063
0.126
0.001
3 ml
0.119
0.238
0.0018
5 ml
0.168
0.338
0.0027
10 ml
0.200
0.400
0.0032

* Total volume is based on the size of the syringe selected.
In Continuous mode it is recommended that the Inderm be pulsed with short pauses to alleviate pressure buildup in the syringe.
Verify that the syringe and needle are purged of air before starting injections.
User testing is recommended to verify the volume is adequate for the intended use.


Injecting Doses

The Inderm is programmed to signal when the injection is completed. The signal is a single beep that follows every injection. This signal is used to allow time for the injection to be absorbed.
   